What do I need to pay attention to in the probe connector?
It can be used for electron probe quantitative analysis, of course, the premise of elemental analysis using electron beam-excited X-rays is that the energy of the incident electron beam is greater than the critical ionization excitation energy of the electrons inside the element atom. So, what do you need to pay attention to the probe connector?
What do I need to pay attention to in the probe connector?
1. In addition to confirming the transportable weight, it is also necessary to confirm the bending direction, torsion direction and comprehensive torque. Please use within the specification values.
2, if not used within the specification range, the opening of the manipulator side and the clamp side will be too large and make a clicking sound.
3. When installing or disassembling the quick replacement fixture in the energized state, the probe front end will be seriously worn.
4. Please turn off the power when installing or disassembling all quick change fixtures.
5, please do not use in water, water vapor, liquid and other dispersed, explosive and corrosive gas environment.
6, when used in an environment with cutting powder, cutting oil, dust and welding slag splashing, it may cause poor electrode electrification.
7, quick exchange fixture is single, if pressure is applied, damage to the machine is very dangerous.
8, before providing air pressure, please install it on the robot or mounting board.
9, quick replacement fixture with the same type of fixture exchange and pairing. The Association will not be liable for any defects or faults that occur when using a quick exchange fixture other than the one used.
10, when the OX series (fixture for quick exchange) is locked and released, the fixture will open and close. When loading and unloading by hand, fingers may be caught on the manipulator side or the fixture side, please use caution.
11. When vacuum is used, the pneumatic self-locking mechanism on the manipulator side needs to be removed for reuse. The method is to remove the plug on the back of the true air path on the side of the manipulator, and then remove the steel ball, spring and seal ring inside, and then install the plug.
12. Regarding the air pressure of locking and unlocking, use the solenoid valve to control the locking. When released, even if the power is off, there is still air pressure on the locked side.
Probe connectors: What is the cleaning of the probe?
1. Regularly clean the contaminants at the probe, and use a dry electrostatic brush when cleaning, parallel to the ground.
2, ensure the cleanliness of the measurement point, avoid rosin, flux and other residues too much.
3, the test should be used in the correct stroke, not overpressure.
4, the temperature of the probe application environment should not exceed the probe set value.
5, in the testing process, there should be no lateral force.
6, the probe test current should not exceed the rated value.
7, when maintaining the test probe on the equipment, try to use professional tools.
The probe connector can be used to deal with poor contact caused by vibration and repeated installation, by changing the electrical contact and using the D-SUB connector, the wiring is simpler.